In contrast to the bridge card, the UA-OFF monitoring board has to be taken into
account when configuring the control.
12.2.9 Possible combinations of base plates and cards
Valve driver boards, 4x, are always combined with two 2x base plates.
Table24 shows the possible combinations of base plates, pneumatic supply
plates, electrical supply plates, and transition plates with various valve driver
boards, bridge cards, and supply boards.
Table22: Possible combinations of plates and cards
Base plate Circuit boards
Base plate, 2x Valve driver board, 2x
Base plate, 3x Valve driver board, 3x
Two base plates, 2x Valve driver board, 4x
Pneumatic supply plate Short bridge card or
UA-OFF monitoring board
Transition plate and pneumatic supply plate Long bridge card
Electrical supply plate Supply board
The boards in the AV-EP base plates are installed permanently and can
therefore not be combined with other base plates.
12.3 Identifying the Modules
12.3.1 Material number for bus coupler
The bus coupler can be clearly identified using its material number. When ex-
changing the bus coupler, you can use the material number to reorder the same
unit.
The material number is printed on the name plate(12) on the back of the device
and on the top below the identification key.
R412018xxx
AES-D-BC-XXX
XX
XX
XX
XX
XX
7291
AES-D-BC-XXXX
R4120XXXXX
12
12.3.2 Material number for valve system
The material number for the complete valve system(46) is printed on the right
end plate. You can use this material number to reorder an identically configured
valve system.
u Note that, after a valve system conversion, the material number still refers to
the original configuration g12.5.5.Conversion documentation.
46
12.3.3 Identification key for bus coupler
R412018xxx
AES-D-BC-XXX
XX
XX
XX
XX
XX
XX
1
The identification key (1) on the top of the AESseries bus coupler for EtherNet/IP
is “AES-D-BC-EIP” and describes the unit’s main characteristics.
12.3.4 Equipment identification for bus coupler
The bus coupler requires a unique ID to enable the clear identification of the unit
within the system. The two equipment identification fields(4) on the top and
front of the bus coupler are available for this purpose.
u Label the two fields as shown in your system diagram.
R412018xxx
AES-D-BC-XXX
XX
XX
XX
XX
XX
XX
4
12.3.5 Bus coupler rating plate
The rating plate is located on the back of the bus coupler. It contains the follow-
ing information:
47
48
49
51
52
53
54
55
56
57
58
7291
AES-D-BC-XXXX
R4120XXXXX
50
Fig.16: Bus coupler rating plate
47 Logo 48 Series
49 Mat. no. 50 MAC address
51 Power supply 52 Manufacture date (FD) with format
“FD:<YY>W<WW>”
53 Serial number 55 Country of manufacture
56 Data Matrix code 57 CE mark
58 Internal plant ID
AVENTICS™ EtherNet/IP | R412018139-BAL-001-AG | English 42