EasyManua.ls Logo

Emerson Digitax ST - Page 161

Emerson Digitax ST
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety
Information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running the
motor
Optimization
EtherCAT
interface
SMARTCARD
Operation
Onboard
PLC
Advanced
parameters
Technical
Data
Diagnostics
UL listing
information
Digitax ST User Guide 161
Issue Number: 5
12.16.3 Digitax ST Plus
Table 12-7 Digitax ST Plus
*See trip SLX.Er, Automation (I/O Expansion) module category
on page 194
.
Parameter
Range(
Ú) Default(Ö)
Type
17.01 Motion processor ID 0 to 599 RO Uni PT US
17.02 Motion processor software version 0.00 to 99.99
RO Uni NC PT
17.03 DPL program status None (0), Stop (1), Run (2), Trip (3)
RO Txt NC PT
17.04 Available system resource 0 to 100
RO Uni NC PT
17.05 RS485 address 0 to 255 11 RW Uni US
17.06 RS485 mode 0 to 255 1 RW Uni US
17.07 RS485 baud rate
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7), 57600 (8),
115200 (9) baud
4800 (4) RW Txt US
17.08 RS485 Turnaround delay 0 to 255 ms 2 RW Uni US
17.09 RS485 Tx enable delay 0 to 1 ms 0 RW Uni US
17.10 DPL Print Routing SYPT: OFF (0), RS485: On (1) SYPT: OFF (0) RW Bit US
17.11 Clock tick time (ms) 0 to 200 10 RW Uni US
17.12 Motion engine sample rate
dISAbLEd (0), 0.25 ms (1), 0.5 ms (2), 1 ms (3),
2 ms (4), 4 ms (5), 8 ms (6)
dISAbLEd (0) RW Txt US
17.13 Enable autorun OFF (0) or On (1) On (1) RW Bit US
17.14 Global run time trip enable OFF (0) or On (1) OFF (0) RW Bit US
17.15 Disable reset on trip cleared OFF (0) or On (1) OFF (0) RW Bit US
17.16 Encoder data update rate 0 to 3 0 RW Uni US
17.17 Enable parameter over range trips OFF (0) or On (1) OFF (0) RW Bit US
17.18 Watchdog enable OFF (0) or On (1) OFF (0) RW Bit US
17.19 Save request OFF (0) or On (1) OFF (0) RW Bit NC
17.20 Enable power down save OFF (0) or On (1) OFF (0) RW Bit US
17.21
Enable menu 20 save and
restore
OFF (0) or On (1) OFF (0) RW Bit US
17.22 CTNet Token Ring ID 0 to 255 0 RW Uni US
17.23 CTNet node address 0 to 255 0 RW Uni US
17.24 CTNet baud rate 5.000 (0), 2.500 (1), 1.250 (2), 0.625 (3) 2.500 (1) RW Txt US
17.25 CTNet sync setup 0,000 to 9,999 0,000 RW Uni US
17.26
CTNet easy mode - first cyclic
parameter destination node
0 to 25,503 0 RW Uni US
17.27
CTNet easy mode - first cyclic source
parameter
0 to 9,999 0 RW Uni US
17.28
CTNet easy mode - second cyclic
parameter destination node
0 to 25,503 0 RW Uni US
17.29
CTNet easy mode - second cyclic
source parameter
0 to 9,999 0 RW Uni US
17.30
CTNet easy mode - third cyclic
parameter destination node
0 to 25,503 0 RW Uni US
17.31
CTNet easy mode - third cyclic source
parameter
0 to 9,999 0 RW Uni US
17.32
CTNet easy mode set-up - Transfer
slot 1 destination parameter
0 to 9,999 0 RW Uni US
17.33
CTNet easy mode set-up - Transfer
slot 2 destination parameter
0 to 9,999 0 RW Uni US
17.34
CTNet easy mode set-up - Transfer
motion processor destination
parameter
0 to 9,999 0 RW Uni US
17.35 CTNet sync event task ID
Disabled (0), Event (1), Event1 (2), Event2 (3),
Event3 (4)
Disabled (0) RW Txt US
17.36 CTNet diagnostic parameter
RO Uni NC PT
17.37 Reject download if drive enabled OFF (0) or On (1) OFF (0) RW Bit US
17.38 Do not trip drive on APC run-time error OFF (0) or On (1) OFF (0) RW Bit US
17.39 Inter-UT70 synchronization status 0 to 3 0 RO Uni NC
17.40 Inter-UT70 master transfer mode 0 to 10 1 RW Uni US
17.41 Indexer control 0 to 3 0 RW Uni NC
17.42 Freeze main drive position OFF (0) or On (1) OFF (0) RW Bit US
17.43 Freeze invert OFF (0) or On (1) OFF (0) RW Bit US
17.44 Task priority level 0 to 255 0 RW Uni US
17.45 User set-up parameter 1
0ROUniNCPT
17.46 User set-up parameter 2
0ROUniNCPT
17.47 User set-up parameter 3
0ROUniNCPT
17.48 DPL line number in error 0 to 2,147,483,647 0 RO Uni NC PT
17.49 User program ID -32,767 to +32,768 0 RO Bi NC PT
17.50 Solutions Module error status* 0 to 255
RO Uni NC PT
17.51
Solutions Module software sub-version
0 to 99 RO Uni NC PT
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not copied RA Rating dependent PT Protected US User save PS Power down save

Table of Contents