DVC6000f Series
March 2006
4-2
Basic Setup
WARNING
Changes to the instrument setup may
cause changes in the output pressure
or valve travel. Depending on the
application, these changes may upset
process control, which may result in
personal injury or propery damage.
When the DVC6000f Series digital valve controller is
ordered as part of a control valve assembly, the
factory mounts the digital valve controller and sets up
the instrument as specified on the order. When
mounting to a valve in the field, the instrument needs
to be setup to match the instrument to the valve and
actuator.
Before beginning basic setup, be sure the instrument
is correctly mounted as described in the Installation
section.
Basic Setup includes the following procedures:
Setup Wizard
Auto Travel Calibrate
Stabilize / Optimize (optional)
Note
The DVC6000f may keep the
Transducer Block Mode
Out-of-Service if the instrument is
not properly mounted.
To setup and calibrate the
instrument, the Transducer Block
Mode must be Manual, and the
Protection must be None.
When using DD methods the
method will request that you
change the mode, but make
changes in Protection
automatically. Protection MUST
NOT BE left as None, as
downloading from a 375 Field
Communicator, DeltaV or other
host system will over write these
parameters.
Table 4-1. DVC6000f Series Factory Default Settings
SETUP PARAMETER DEFAULT SETTING
Tvl Cutoff Hi
Tvl Cutoff Lo
Tvl Integral Gain
Tvl Cal Trigger
99.5%
0.5%
9.4 repeats/min
No
Tvl Integ Enable
Tvl Integ Lim Hi
Tvl Integ Lim Lo
Tvl Integ DeadZ
On
30%
30%
0.25%
Press Cutoff Hi
Press Cutoff Lo
Press Integ DeadZ
Press Integ Hi Lim
Press Integ Lo Lim
99.5%
0.5%
0.25%
20.0%
20.0%
Input Char
Shutdown Trigger
Shutdown Recovery
Output Blk Timeout
Linear
All Off
All Off
600 sec
Trans Block Mode
(TB > Detailed Setup > Trans Block Mode)
To setup and calibrate the instrument, the transducer
block mode must be in Manual. For more information
about transducer block mode, refer to page 5-23.
Protection
(TB > Detailed Setup > Protection)
To setup and calibrate the instrument, the protection
must be set to None with the Field Communicator (for
information on using the 375 Field Communicator,
refer to 375 Field Communicator Basics, Section 3 of
this manual). For more information about configuration
protection refer to page 5-23.
Setup Wizard
(TB > Basic Setup > Setup Wizard)
To have the Field Communicator automatically setup
the instrument using specified actuator information,
from the Menu select Transducer Block, Basic Setup,
and Setup Wizard. Follow the prompts on the Field
Communicator display to setup the instrument. Table
4-2 provides the actuator information required to setup
and calibrate the instrument.
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher Fieldvue DVC6020f and is the answer not in the manual?

Emerson Fisher Fieldvue DVC6020f Specifications

General IconGeneral
BrandEmerson
ModelFisher Fieldvue DVC6020f
CategoryController
LanguageEnglish

Related product manuals