1.6.1  Maximum cable lengths between sensor and transmitter
The maximum cable length between the sensor and transmitter, which are installed
separately, is determined by cable type.
Cable type Wire gauge Maximum length
MicroMotion 4-wire remote
mount
Installation specific 1,000ft (305m) without Ex-
approval
500ft (152m) with IIC rated
sensors
1,000ft (305m) with IIB
rated sensors
MicroMotion 9-wire remote
mount
Installation specific 1,000ft (305m)
(1)
User-supplied 4-wire VDC 22AWG (0.326mm²) 300ft (91m)
VDC 20AWG (0.518mm²) 500ft (152m)
VDC 18AWG (0.823mm²) 1,000ft (305m)
RS-485 22AWG (0.326mm²) or
larger
1,000ft (305m)
(1) For Smart Meter Verification, the limit is 60ft (18m).