11.1.7  EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof and
Dust Ignition-proof
Certificate
EAЭC KZ 7500525.01.01.00672
Markings
0/1 Ex db IIC T6…T4 Ga/Gb X
Ex ta IIIC T105°C T
500
95°C Da X
IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate
EAЭC KZ 7500525.01.01.00672
Markings
0Ex ia IIC T4 Ga X
11.1.8  Japan
E4 Japan Flameproof
Certificate
CML 17JPN1147X
Markings
Ex db IIC T6…T4 Ga/Gb
Temperat
ure class
Ambient temperature Process temperature
T6 –60 to +70 °C –60 to +70 °C
T5 –60 to +80 °C –60 to +80 °C
T4 –60 to +80 °C –60 to +120 °C
Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm less than 1 mm
thickness that forms a boundary between EPL Ga (process
connection) and EPL Gb (all other parts of the equipment).
The model code and datasheet are to be consulted for details
of the diaphragm material. Installation, maintenance, and
use shall consider the environmental conditions to which the
diaphragm will be subjected. The manufacturer’s instructions
for installation and maintenance shall be followed in detail to
assure safety during its expected lifetime.
2. Flameproof joints are not intended for repair.
3. Non-standard paint options may cause risk from electrostatic
discharge. Avoid installations that could cause electrostatic
build-up on painted surfaces, and only clean the painted
surfaces with a damp cloth. If paint is ordered through
a special option code, contact the manufacturer for more
information.