6 Flow configuration
Rosemount
3051SMV Engineering Assistant 6.1 or later
The Rosemount 3051SMV Engineering Assistant is designed to guide the user
through the setup of the flow configuration for a Rosemount 3051SMV. The
flow configuration screens allow the user to specify the fluid, operating
conditions, and information about the primary element, including inside pipe
diameter. This information will be used by the Rosemount 3051SMV
Engineering Assistant software to create flow configuration parameters that
will be sent to the transmitter or saved for future use.
Online and offline modes
The Engineering Assistant software can be used in two modes: Online and
Offline. In Online mode, the user can receive the configuration from the
transmitter, edit the configuration, send the changed configuration to the
transmitter, or save the configuration to a file. In offline mode, the user can
create a new flow configuration and save the configuration to a file or open
and modify an existing file.
The following pages provide instructions on creating a new flow configuration
in offline mode. For more information on other functionality, see the
Rosemount 3051SMV Reference Manual.
October 2018 Quick Start Guide
Quick Start Guide 17

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount MultiVariable 3051S Series and is the answer not in the manual?

Emerson Rosemount MultiVariable 3051S Series Specifications

General IconGeneral
TypeMultiVariable Transmitter
Accuracy±0.04% of span
Ambient Temperature Limit-40 to 185 °F (-40 to 85 °C)
ApprovalsFM, CSA, ATEX, IECEx
ServiceLiquid, Gas, Steam
Warranty5 years
Process Temperature Range-40 to 257°F (-40 to 125°C)
Response Time100 ms
Power Supply10.5 to 42 V DC
Communication ProtocolsHART, FOUNDATION Fieldbus, PROFIBUS
Housing MaterialAluminum
DisplayOptional LCD
Process Connection1/4" NPT
Electrical Connection1/2–14 NPT, M20 x 1.5
Enclosure RatingNEMA 4X, IP66
Measurement TypesDifferential Pressure, Static Pressure, Temperature