112 Unidrive SP Regen Installation Guide
www.controltechniques.com Issue Number: 2
Table 9-6 Regen mode state diagram
Table 9-7 Regen mode states
Table 9-8 Menu 6 Regen parameter descriptions
State Actions Exit conditions
DISABLE Disable inverter
1. TripState! = NO_TRIP THEN TRIP_STATE
2. Enable THEN SYNC_STATE
REGEN_SYNC Enable inverter
1. TripState! = NO_TRIP THEN TRIP_STATE
2. Not Enable THEN DISABLE_STATE
3. Supply not okay THEN DISABLE_STATE
4. Synchronised THEN ACTIVE_STATE
REGEN_ACTIVE
1. TripState! = NO_TRIP THEN TRIP_STATE
2. Not Enable OR NOT synchronised THEN DISABLE_STATE
TRIP Disable inverter 1. TripState! = NO_TRIP THEN DISABLE_STATE
Drive Status Conditions Display
INHIBIT DISABLE_STATE inh
READY Not used
STOP Not used
SCAN SYNC_STATE SCAn
RUN Not used
ACUU Not used
DECEL Not used
DC_INJ Not used
ORIENTING Not used
TRIPPED TRIPPED_STATE trip
REGEN_ACTIVE ACTIVE_STATE act
Parameter
Range(
Ú) Default(Ö)
Type
6.15 Drive enable OFF (0) or On (1) On (1) RW Bit US
6.16 Electricity cost per kWh 0.0 to 600.0 currency units per kWh 0.0 RW Uni US
6.17 Reset energy meter OFF (0) or On (1) OFF (0) RW Bit NC
6.18 Time between filter changes 0 to 30,000 hrs 0 RW Uni NC US
6.19 Filter change required / change done OFF (0) or On (1) OFF (0) RW Bit PT
6.20 Powered-up time: years.days 0 to 9.364 years.days RW Uni NC PT
6.21 Powered-up time: hours.minutes 0 to 23.59 hours.minutes RW Uni NC PT
6.22 Run time: years.days 0 to 9.364 years.days RO Uni NC PT PS
6.23 Run time: hours.minutes 0 to 23.59 hours.minutes RO Uni NC PT PS
6.24 Energy meter: MWh ±999.9 MWh RO Bi NC PT PS
6.25 Energy meter: kWh ±99.99 kWh RO Bi NC PT PS
6.26 Running cost ±32,000 RO Bi NC PT
6.27 Time before filter change due 0 to 30,000 hrs RO Uni NC PT PS
6.28 Select clock for trip log time sampling OFF (0) or On (1) OFF (0) RW Bit US
6.29 Hardware enable OFF (0) or On (1) RO Bit NC PT
6.41 Drive event flags 0 to 65,535 0 RW Uni NC
6.42 Control word 0 to 32,767 0 RW Uni NC
6.43 Control word enable OFF (0) or On (1) OFF (0) RW Bit US
6.44 Active supply OFF (0) or On (1) RO Bit NC PT
6.45 Force cooling fan to run at full speed OFF (0) or On (1) OFF (0) RW Bit US
6.46 Normal low voltage supply Size 1: 48V, Size 2 and 3: 48V to 72V 48 RW Uni PT US
6.49
Disable multi-module drive module
number storing on trip
OFF (0) or On (1) OFF (0) RW Bit US
6.50 Drive comms state 0 to 3 RO Txt NC PT
RW Read / Write RO Read only Uni Unipolar Bi Bi-polar Bit Bit parameter Txt Text string
FI Filtered DE Destination NC Not cloned RA Rating dependent PT Protected US User save PS Power down save