14 Unidrive SP Regen Installation Guide
www.controltechniques.com Issue Number: 2
Table 3-2 400V drive ratings (380V to 480V ±10%)
The SPMD1404 can deliver 350A continuously only if the ambient is 35
°
C or lower and it is docked to the SPMC. Under all other circumstances the current rating is 335A.
The above current ratings are given for max 40°C (104°F), and 3.0 kHz switching. Derating is required for higher switching frequencies, ambient
temperature >40°C (104°F) and high altitude. For further information, refer to both the Unidrive SP and SPM User Guides.
Model
Normal Duty Heavy Duty
Maximum
continuous
input current
Typical motor
power
at 400V
Typical motor
power
at 460V
Maximum
continuous
input current
Typical motor
power
at 400V
Typical motor
power
at 460V
AkWhpAkWhp
1405 8.8 4.0 5.0 7.6 3.0 5.0
1406 11 5.5 7.5 9.5 4.0 5.0
2401 15.3 7.5 10 13 5.5 10
2402 21 11 15 16.5 7.5 10
2403 29 15 20 25 11 20
2404
29 15 20
3401 35 18.5 25 32 15 25
3402 43 22 30 40 18.5 30
3403 56 30 40 46 22 30
4401 68 37 50 60 30 50
4402 83 45 60 74 37 60
4403 104 55 75 96 45 75
5401 138 75 100 124 55 100
5402 168 90 125 156 75 125
6401 202 110 150 180 90 150
6402 236 132 200 210 110 150
1401 205 110 150 180 90 150
1402 236 132 200 210 110 150
1401 205 110 150 180 90 150
1402 246 132 200 210 110 150
1403 290 160 250 246 132 200
1404 350 200 300 290 160 250
1
2
3
4
55
56
SPMA
SPMD
NOTE

Table of Contents