The ERTune™ Program: Basic Features
The Mechanical Regulator Panel
The elds in this panel display the series number, model number
and serial number for the regulator that the ER5000 controls. You
enter this information during setup.
If you change regulators, you can update the information here.
To change the Regulator Series
1. Click the Down Arrow (
▼
) of the Mechanical Regulator Series drop-
down list.
2. Select a different TESCOM™ series number or, if appropriate,
select Other or None.
NOTENOTE
CAUTIONCAUTION
WARNINGWARNING
The ERTune™ program automatically checks for PIDs
included with the software that are optimized for the Regulator
Series you have selected. If you click the Yes button, the new
settings will be downloaded to the ER5000. If you click the No
button, the current settings will be used.
To change the regulator model number or serial number
1. Enter a new value in the Model Number or Serial Number entry
eld and press the Tab key.
The ER Settings Panel
The elds in this panel control the basic conguration of the ER5000.
ER Model #
This drop-down list allows you to change the model number of
the ER5000.
Control Mode
This drop-down list allows you to change the feedback source
(Control Mode) for the ER5000.
To change the Control Mode of the ER5000
1. Click the Down Arrow (
▼
) of the Control Mode drop-down list.
Select Internal Feedback, External Feedback or Cascade.
NOTENOTE
CAUTIONCAUTION
WARNINGWARNING
You may need to tune the ER5000 after changing the
Control Mode. Refer to The Tuning Tab: Controls and Functions for
Tuning the ER5000 for procedures and tips for tuning the ER5000.