Figure 3-10 Removal of size 9E and 10 line to ground varistors
To electrically disconnect the line to ground varistors, remove the screw as highlighted above (1).
The Internal EMC filter on size 9E and 10 cannot be removed.
The line to ground varistors should only be removed in special circumstances such as ungrounded
supplies with more than one source, for example on ships. Contact the supplier of the drive for more
information.
3.8.2 External filter
The external EMC filter for size 3, 4, 5 and 6 can be footprint or bookcase mounted.
For information on drive and EMC filter cross reference, refer to the Drive User Guide.
For further information refer to the Drive User Guide.
To avoid a fire hazard and maintain validity of the UL listing, adhere to the specified
tightening torques for the power and ground terminals.