00.037 Serial Address {11.023} 1 to 247 1 RW Num US
00.038
Current
Controller Kp
Gain
{04.013} 0 to 30000 20 150 RW Num US
00.039
Current
Controller Ki
Gain
{04.014} 0 to 30000 40 2000 RW Num US
00.040 Auto-tune {05.012} 0 to 2 0 to 5 0 to 6 0 RW Num NC
00.041
Maximum
Switching
Frequency
{05.018}
2 kHz (0), 3 kHz (1), 4 kHz (2),
6 kHz (3), 8 kHz (4),
12 kHz (5), 16 kHz (6)
3 kHz (1) RW Txt RA US
00.042
Number Of
Motor Poles
{05.011} Automatic (0) to 480 Poles (240) Automatic (0)
6
Poles
(3)
RW Num US
00.043
Rated Power
Factor
{05.010} 0.000 to 1.000
0.850 RW Num RA US
00.044 Rated Voltage {05.009} ±VM_AC_VOLTAGE_SET V
200V drive: 230V
50Hz default
400V drive: 400V
60Hz default
400V drive: 460V 575V
drive: 575V
RW Num RA US
00.045 Rated Speed {05.008}
0 to
33000 rpm
0.00 to
33000.00
rpm
Eur -
1500
rpm
USA -
1800
rpm
Eur -
1450.0
0 rpm
USA -
1750.0
0 rpm
3000.
00
rpm
RW Num US
00.046 Rated Current {05.007} ±VM_RATED_CURRENT A
Maximum Heavy Duty
Rating (11.032) A
RW Num RA US
00.047
Rated
Frequency
{05.006} 0.0 to 550.0 Hz
50Hz: 50.0
60Hz: 60.0
RW Num US
Volts per 1000
rpm
{05.033}
0 to
10000 V
/ 1000
rpm
98 V /
1000
rpm
RW Num US
00.048 User Drive Mode {11.031}
Open-loop (1), RFC-A (2),
RFC-S (3),
Regen (4)
Open-
loop (1)
RFC-A
(2)
RFC-
S (3)
RW Txt ND NC PT
00.049
User Security
Status
{11.044}
Menu 0 (0), All Menus (1),
Read-only Menu 0 (2),
Read-only (3), Status Only (4),
No Access (5)
Menu 0 (0) RW Txt ND PT
00.050 Software Version {11.029} 0 to 99999999 RO Num ND NC PT
00.051
Action On Trip
Detection
{10.037} 00000 to 11111 00000 RW Bin US
00.052
Reset Serial
Communications
{11.020} Off (0) or On (1) Off (0) RW Bit ND NC
00.053
Motor Thermal
Time Constant 1
{04.015} 1.0to3000.0s 89.0s RW Num US
00.054
RFC Low
Speed Mode
{05.064}
Injection
(0),
Non-
salient
(1)
Non-
salient
(1)
RW Txt US
00.055
Low Speed
Sensorless
Mode Current
{05.071}
0.0 to
1000.0
%
20.0
%
RW Num RA US
00.056 No-load Lq {05.072}
0.000 to
500.000
mH
0.000
mH
RW Num RA US
Parameter
Range Default
Type
OL RFC-A RFC-S OL RFC-A RFC-S