66
GBGB
7. INFRARED REMOTE CONTROL
Attention
In order to safeguard the proper functioning of the compressor, it is
foreseen that
- Once stopped, it will not restart earlier than 3 minutes.
- Once started, it will operate for at least 6 minutes (unless the unit
is switched off)
- Changing the modes during the operation, it may happen that the
unit does not respond immediately. Please wait 3 minutes.
- During the heating function a system of cold currents prevention is
activated. After 2-5 minutes the indoor heat exchanger will start to
make the fan working and the temperature begins to increase.
- Please wait 3 minutes before restarting the unit.
Models: Dual / Trial / Quadrial
The indoor units must be put into service in the same operational mode
or in compatibility mode according to the table below
Cooling Dry Heating Fan
Cooling √ √ X √
Dry √ √ X √
Heating X X √ X
Fan √ √ X √
√= Norm X= Interference
The outdoor unit always operates in the mode of the first indoor unittur-
ned/on. If a subsequent indoor unit is set in a way that interferes with
the first one, the unit that has caused the interference will be automa-
tically turned off.
Automatic
High Average
Low
7.2 Operation in ventilation FAN ONLY
1 Press the MODE button to select the operating mode
FAN
ONLY.
The air conditioner recirculates the ambient air without heating or
cooling. In FAN ONLY mode, only HIGH, MEDIUM and LOW speeds
are available.
2 Press Button
FAN SPEED select the desired speed fan: