- 161 -
Chapter 9. Standard Input/ Output Signal
27) Absolute position setting signal(in) ZS ZS1[
M94.E
], ZS2[
M94.F
]
If the input signal ZS1,ZS2 changes to open(0) Æ close(1), then the absolute coordinate of
the relevant axis changes to a setting value of the Position table P99.
28) MPG interpolation feed(in) Mra[
M97.E
]
If the input signal of Mra[
M97.E
] is closed(1), then the XY can be simultaneously moved in
the slope of the variable ‘L99’ setting value.
For example, if the L99 value is 30000(unit:0.001˚), then it will move by the MPG like the
figure below.
30
X
Y