EasyManua.ls Logo

EMP OP80 - Technical Information; Specifications

Default Icon
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
© 2019 EMP, Inc. 9
Technical Information
Operation
Connector, operation, and wiring information are in the appendices, depending on the pump model.
Model OP80 pumps are explained in Appendix A
, Operation Manual R20L Controller Board.
Model OP80C pumps are explained in Appendix B, Operation Manual R20C Controller Board.
Specifications
*NOTE: Reference the pump performance charts for the typical performance capability of the oil pump
using a light weight oil.
NOTE: Performance will be reduced at lower operating temperatures when using lower voltage power
supplies and when using heavier weight oils.
Component Construction
Cast Aluminum
Performance
Model: 12V and 24V
Theoretical Displacement 0.468 in
3
/rev (7.67 cm
3
/rev)
Flow Capacity Maximum* 8.0 gal/min (30 L/min)
Operating Pressure Maximum* 80 psi (5.5 Bar)
Operating Temperature Maximum (Air)
203
°F (95 °C)
Operating Temperature Maximum (Oil)
212
°F (100 °C)
Operating Temperature Minimum
32
°F (0 °C)*
(*Sub-zero operation is application dependent)
Oil Viscosity Maximum
~5000 cSt
(Current models optimized for lighter weight oils like ATF)
Motor Speed Maximum 5000 rpm
Motor Speed Minimum 500 rpm
Motor Speed Default
4000 rpm (configurable)
Mechanical Connections
Model: 12V and 24V
Suction SAE STOR -10 (7/8-14 UNF-2B)
Discharge SAE STOR -8 (3/4-16 UNF-2B)
Weight
Model: 12V and 24V
Component Weight 9.5 lbs (4.3 kg)
Electrical
Model: 12V
Model: 24V
Input Voltage 9–16 V DC (14 V nominal) 1832 V DC (28 V nominal)
Operating Current Draw Maximum
25 A
25 A
Thermal Protection Auto self-protect shutdown Auto self-protect shutdown

Table of Contents

Other manuals for EMP OP80

Related product manuals