EL – Owner’s Manual – Rev.04 – April 2022 23
This is a draft manual, technical specifications are subject to change
4.5.2 WATER INLET CONNECTION GUIDE (H
2
O IN)
The water inlet connector is a push-fit bulkhead, for an outside pipe diameter of 10 mm. This inlet port
is used for the automatic refilling of demineralised water from a pressurised source.
Warning!
Ensure water pressure on the input line never exceeds the maximum allowed pressure. This
can cause irreparable damage to the device and create significant leakages. Enapter is not
responsible for any damage or injury resulting from the misuse of the device.
Attention!
Ensure your water input quality is sufficient. Demineralised water with a higher conductivity
than stated in the datasheet will irremediably damage the stack. The same applies for particles
and debris in the demineralised water. Install filters at the water inlet of the device and clean
them regularly to ensure that the water is free of particles. If a device is damaged from using
low-quality water, Enapter is not responsible for any damage caused.
Flush all water pipes with demineralised water before connecting your device to ensure no debris is in
the lines. Then connect the “H
2
O IN” port located at the top left of the front panel directly to your water
supply.