EasyManua.ls Logo

Enapter Electrolyser - Page 40

Enapter Electrolyser
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VERSION
DOCUMENT TITLE
03
EL Owner’s Manual
EL Owner’s Manual – Rev.04 April 2022 34
This is a draft manual, technical specifications are subject to change
If you want to refill the device during regular maintenance, you will need to repeat the steps of draining
and filling the electrolyte a few times. This ensures, that contaminations inside the tank are kept at a
minimum. The Enapter app will automatically guide you through the process.
Time required
5 minutes
Materials required
Safety Glasses
Nitrile Gloves
2 L of 1% KOH solution
To prepare the electrolyser for operation, before demineralised water is added automatically, it must
be filled with the electrolyte which is included in the shipment. If it is not included, it can typically be
procured or purchased locally. Please refer to 0 below.
Warning! Refer to the Material Safety Data Sheet (MSDS) of all chemicals used, before
handling them. All persons using, preparing, and filling the electrolyte into the device
must be informed about any potential hazards involved with their activities.
Attention: Follow industrial hygiene and safety practice and wear appropriate Personal
Protective Equipment. Avoid any contact with eyes and skin.
Attention: Ensure all material used to store and contain your electrolyte solution is
chemically compatible with its contents.

Other manuals for Enapter Electrolyser

Related product manuals