Appendix Cerabar M, Deltabar M, Deltapilot M / 4...20 mA HART
128 Endress+Hauser
Expert È Diagnosis È Diagnostic list
Expert È Diagnosis È Event logbook
Reset peakhold (161)
Selection
You can reset the "Min. meas. press." and "Max. meas. press." indicators with this
parameter.
Options:
Abort
•Confirm
Factory setting:
Abort
Operating hours (162)
Display
Displays the hours of operation. This parameter cannot be reset.
Config. counter (100)
Display
Displays the configuration counter.
This counter is increased by one every time a parameter or group is changed. The counter
counts up to 65535 and then starts again at zero.
Parameter name Description
Diagnostic 1 (075)
Diagnostic 2 (076)
Diagnostic 3 (077)
Diagnostic 4 (078)
Diagnostic 5 (079)
Diagnostic 6 (080)
Diagnostic 7 (081)
Diagnostic 8 (082)
Diagnostic 9 (083)
Diagnostic 10 (084)
These parameters contain up to ten diagnosis messages that are currently pending,
arranged in order of priority.
Parameter name Description
Last diag. 1 (085)
Last diag. 2 (086)
Last diag. 3 (087)
Last diag. 4 (088)
Last diag. 5 (089)
Last diag. 6 (090)
Last diag. 7 (091)
Last diag. 8 (092)
Last diag. 9 (093)
Last diag. 10 (094)
These parameters contain the last 10 diagnosis messages to occur and be rectified.
They can be reset with the "Reset logbook" parameter.
Errors which have occurred multiple times are displayed once only.
Parameter name Description