Levelflex FMP56, FMP57
Endress+Hauser 27
Mounting in non-metallic vessels
A0012527
1 Non-metallic vessel
2 Metal sheet or metal flange
To measure, Levelflex with a rod probe needs a metallic surface at the process connection. Therefore:
• Select an instrument version with metal flange (minimum size DN50/2").
• Or: mount a metal sheet with a diameter of at least 200 mm (8") to the probe at the process connection. Its
orientation must be perpendicular to the probe.
Installation with heat insulation
• If process temperatures are high, the device must be included in normal tank insulation to prevent the
electronics heating up as a result of heat radiation or convection.
• The insulation may not exceed beyond the points labeled "MAX" in the drawings.
Process connection with thread
A0014143
1
Tank insulation