Basic specification, Position 1 (Approval) = C (only Ex nA, Ex tc)
Basic specification, Position 7
(Electronics; Output)
Supply
A U = 9 to 32 V
DC
; connection only to PROFIBUS PA
I
max
≤ 13.5 mA
D, 9 U = 21 to 26 V; connection only to FML621
I
max
≤ 16 mA
1 U = 19 to 253 V
AC
, 50/60 Hz; P
max
≤ 0.83 W
I
max
≤ 350 mA
2 U = 10 to 55 V
DC
; P
max
≤ 0.83 W
I
max
≤ 350 mA
5 U = 11 to 36 V
DC
; P
max
≤ 0.6 W
I
max
≤ 22 mA
6, 8 U = 4 to 12.5 V
DC
; P
max
≤ 23 mW
I
max
≤ 3.5 mA
7 U = 9.5 to 12.5 V
DC
; P
max
≤ 150 mW
I
max
≤ 13 mA
Basic specification, Position 1 (Approval) = C (only Ex ic)
Basic specification, Position 7
(Electronics; Output)
Supply
A U
i
= 17.5 V
P
i
= 5.5 W
I
i
= 500 mA
C
i
= 2.7 nF
L
i
= 10 µH
Fieldbus: PROFIBUS PA
D
1)
U
i
= 27.6 V
P
i
= 640 mW
I
i
= 93 mA
C
i
= 2 nF
L
i
= 0.133 mH
Only power supply unit FML621 from
Endress+Hauser
5 U
i
= 36 V
P
i
= 1 W
I
i
= 100 mA
C
i
/L
i
= 0
Power supply unit with maximum electrical
specifications below the characteristic values of the
electronic inserts
6, 8 U
i
= 16 V
P
i
= 170 mW
I
i
= 52 mA
C
i
/L
i
= 0
Power supply unit with maximum electrical
specifications below the characteristic values of the
electronic inserts
7 U
i
= 16.7 V
P
i
= 1 W
I
i
= 150 mA
C
i
/L
i
= 0
Power supply unit with maximum electrical
specifications below the characteristic values of the
electronic inserts
1) only FTL50(H), FTL51(H), FTL51C