Liquiphant M, Liquiphant S FTL50(H)/51(H)/51C, FTL70/71 XA00182F-F
Endress+Hauser 27
Device type FTL70, FTL71, Basic specification, Position 11 (Application) = L, N, Y
40
60
32
T
a
T
a
T
p
0
0
230 280
–60
–60
300
70
70
0
0
NL1.2
1.1
Y
–50
–50
T
p
230190 280
300
NL Y
T
a
T
a
T
p
T
p
40
60
32
A0027415
 8
T
a
Ambient temperature in °C
T
p
Process temperature in °C
1 Temperature separator:
1.1 insulated
1.2 free-standing
2 Basic specification, Position 7 (Electronics; Output) = 4: –50 °C ≤ T
a
≤ +40 °C (T6)
3 Basic specification, Position 7 (Electronics; Output) = A, 9: –50 °C ≤ T
a
≤ +60 °C (T6)
Connection data
Basic specification, Position 1 (Approval) = B
Basic specification, Position 7
(Electronics; Output)
Supply
4 U = 19 to 253 V
AC
, 50/60 Hz; P
max
≤ 1.3 W
or
U = 19 to 55 V
DC
Relay:
I
max
 6.0 A → U
max
= 253 V
AC
;
I
max
 6.0 A → U
max
= 30 V
DC
I
max
 0.2 A → U
max
≤ 125 V
DC
P
max
= 1 500 VA, cos φ = 1
P
max
= 750 VA, cos φ > 0.7