XA00182F-F Liquiphant M, Liquiphant S FTL50(H)/51(H)/51C, FTL70/71
38 Endress+Hauser
Type d'appareil FTL70, FTL71, Spécifications de base, Position 11 (Application) = L, N, Y
Classe de
température
Spécifications de base,
Position 7
(Electronique; sortie)
Température ambiante T
a
(ambient) : Electronique
Température de process T
p
(process) : Capteur
T6 4 –50…+40 °C –60…+85 °C
A, 1, 2, 5, 6, 7, 8, 9 –50…+60 °C
T5 4
1)
–50…+55 °C –60…+100 °C
A, 1, 2, 5, 6, 7, 8, 9
1)
–50…+70 °C
T4 tous
1)
–50…+70 °C –60…+135 °C
T3 tous
1)
–50…+70 °C –60…+200 °C
T2 tous
1)
–50…+70 °C –60…+230 °C (L)
tous
1)
–50…+70 °C –60…+280 °C (N)
tous
1)
–50…+70 °C –60…+300 °C (Y)
1) Restrictions →  12,  39
Type d'appareil FTL50(H)/51(H),
Spécifications de base, Position 5, 6 (Longueur de sonde; type) = Ix, Qx, Jx, Kx, Lx, Rx, Sx, Tx
Type d'appareil FTL51C,
Spécifications de base, Position 5, 6 (Longueur de sonde; type) = xK, xL, xM, xN, xS
T
a
T
p
T
a
T
p
40
60
0
90 120
–50 150
70
0
4 A32
1
5
–50
A0025549
 11
T
a
Température ambiante en °C
T
p
Température de process en °C
A Gamme de température utile supplémentaire pour appareils avec Spécifications de base, Position 5, 6
(Longueur de sonde; type) FTL50(H) = Ix, Qx et FTL51(H) = Jx, Kx, Lx, Rx, Sx, Tx
1 Entretoise de température ou traversée étanche à la pression
2 Spécifications de base, Position 7 (Electronique; sortie) = 4 : –50 °C ≤ T
a
≤ +40 °C (T6)
3 Spécifications de base, Position 7 (Electronique; sortie) = A, D : –50 °C ≤ T
a
≤ +60 °C (T6)
4 ECTFE (xK)
5 PFA, émail (xL, xM, xN, xS)