Enter slope
0.200 … 5.000
1.000
Function group
SLOPE
V
V
V2
N2
V3
N3
Store slope
no; newyes;
V4
N4
V1
N1
C
C115
C111
C112
C113
C114
C1 (6)
C1 (5)
C1 (4)
C1 (3)
C1 (2)
C1 (1)
C135
C132C131 C133 C134
C123
C121
C122
C141
C142
C143
C153
C151
C152
C161
C162
C163 C164
C165
Measured value display
Current input in %
Measured value display
Current input in mA
B
B1
B2 B3
B4
B5
B6
A
A1
A2
A4A3
A5
Enter offsetFunction group
OFFSET
Calibration status
is displayed
o.k.
E---
Calibration status
is displayed
o.k.
E---
Store offset
no; newyes;
Enter absolute value
current measured value
Enter absolute value
current measured value
Function group
CALIBRATION
Store calibration
result
no; newyes;
Entry of concentration
of first calibration solution
100.0 FNU;
100.0 ppm (mg/l);
10.0 g/l; 10.0 %
.
Entry of concentration
fo second cal. solution
last calibration value
C112 C111 × 1.1³
Entry of concentration
of third calibration solution
last calibration value
C113 C112 × 1.1³
.
Calibration status
is displayed
o.k.
E---
Calibration selection
Data
= calibration data;
only C1 (6) is available
for data set 1
1-pt = 1-point
calibration
Refl
= reflection
compensation
Edit = edit
calibration
Corr
= 3-point correction
3-pt = 3-point
calibration
Store calibration
result
no; newyes;
Entry of concentration
of second cal. solution
> value in C131 × 11
current value in C112
Entry of concentration
of first calibration solution
entire measuring range
current value in C111
Entry of concentration
of third calibration solution
> value in C132 × 1.1
current value in C113
Calibration status
is displayed
o.k.
E---
Store calibration
results
; no; newyes
Entry of correct
concentration of
calibration solution 3
entire meas. range
current value in C113
Calibration status
is displayed
o.k.
E---
Entry of correct
measured value
0 ... 2.0 FNU
0 ... 5.0 ppm (mg/l)
0;
0;
Calibration status
is displayed
o.k.
E---
Store calibration
results
; no; newyes
Store calibration
results
; no; newyes
Entry of current
calibration value
entire measuring range
current measured value
Calibration status
is displayed
o.k.
E---
Display of cal. point 1
comparative value
Display of cal. point 2
comparative value
Display of cal. point 3
comparative value
Display of
slope 1
current value
Display of
slope 2
current value
MEAS. VALUE DISPLAY
with
TEMPERATURE DISPLAY
in °C
Measured value display
in FNU
Temperature display
suppressed
Temperature display
in °F
Other errors are
displayed
(up to 10 errors)
1st error is displayed
(if present)
Edit mode:
Code 22
Read mode:
any code
Edit mode:
Code 22
Read mode:
any code
Function group
SETUP 2
Switch wiper control
on or off
on
off
Set duration of
wiper operation
3 ... 999 s
30
Set pause time between
wiper cycles
1 ... 7200 min
120 min
Selection of calibration
data set used
1 ... 3
3
Copy data sets
12;13
23;32
no
®®
®®
Display of measured value
with reflection compensation
;noyes
Function group
SETUP 1
Selection of oper. mode
; ppm; mg/l; g/l;
%; spec.
FNU
Selection of unit
displayed (if A1=spec)
; t/m
%; none
kg/l
3
Display of sensor
connected
; CUS 41CUS 31
Display format selection
(if A1=spec)
; X.xxx; XXX.x; XXXXXX.xx
Entry of damping
(1=no damping)
1-60
10