Endress+Hauser Micropilot FMR20 - Incoming acceptance and product identification; Goods acceptance; Product identification

Endress+Hauser Micropilot FMR20
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR20 HART
12 Endress+Hauser
Block diagram of HART device, RIA15 with installed HART communication resistor module
The HART communication module for installation in the RIA15 can be ordered together with
the device.
Product structure, feature 620 "Accessory enclosed":
Option R6 "HART communication resistor hazardous / non-hazardous area"
The voltage drop to be taken into account is:
Max. 7 V
Alternatively available as an accessory, for details see Technical Information TI01043K and
Operating Instructions BA01170K
Connection of the HART communication resistor module, RIA15 without backlighting
1
LED
-
+
3
2
Y
I
R
s
DC
A0020839
 7 Block diagram of HART device, RIA15 without light, HART communication resistor module
1 HART communication resistor module
2 Device with HART communication
3 Power supply
Connection of the HART communication resistor module, RIA15 with backlighting
1
3
2
Y
I
R
s
DC
LED
-
+
A0020840
 8 Block diagram of HART device, RIA15 with light, HART communication resistor module
1 HART communication resistor module
2 Device with HART communication
3 Power supply
Cable specification
Unshielded cable, wire cross-section 0.75 mm
2
Resistant to UV and weather conditions as per ISO 4892-2
Flame resistance according to IEC 60332-1-2
As per IEC/EN 60079-11 section 10.9, the cable is designed for a tensile strength of 30 N (6.74 lbf)
(over a period of 1 h).
The device is supplied with 5 m (16 ft) cable length as standard. Cable lengths 10 m (33 ft) and
20 m (66 ft) are optionally available.
Lengths can be selected by the user up to an overall length of 300 m (980 ft) and are available by the
meter (order option "8") or foot (order option "A").
Overvoltage protection
The device is equipped with integrated overvoltage protection.