Micropilot FMR50/51/52/53/54/56/57 XA00688F-A
Endress+Hauser 33
Antenne und Elektronikgehäuse / Antenna and electronics housing /
Antenne et boîtier de l'électronique: Zone 1
FMR51
Position 3 (Hilfsenergie; Ausgang / Power Supply; Output / Alimentation; Sortie) = E, G (TRC [27])
Position 5 (Gehäuse / Housing / Boîtier) = B
Hilfsenergie; Ausgang /
Power Supply; Output /
Alimentation; Sortie
Temperaturklasse /
Temperature class /
Classe de température
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
1 Kanal benutzt /
1 channel used /
1 voie utilisée
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 54 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 69 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 80 °C 81 °C 80 °C 135 °C 69 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 80 °C 81 °C 80 °C 150 °C 66 °C 150 °C –40 °C –40 °C –40 °C - -
2 Kanäle benutzt /
2 channels used /
2 voies utilisées
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 54 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 69 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 76 °C 76 °C 76 °C 135 °C 63 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 76 °C 76 °C 76 °C 150 °C 60 °C 150 °C –40 °C –40 °C –40 °C - -
Position 5 (Gehäuse / Housing / Boîtier) = C
Hilfsenergie; Ausgang /
Power Supply; Output /
Alimentation; Sortie
Temperaturklasse /
Temperature class /
Classe de température
P 1 P 2 P 3 P 4 P 5 P 6
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
T
p
T
a
1 Kanal benutzt /
1 channel used /
1 voie utilisée
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 55 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 70 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 80 °C 81 °C 80 °C 135 °C 71 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 80 °C 81 °C 80 °C 150 °C 68 °C 150 °C –40 °C –40 °C –40 °C - -
2 Kanäle benutzt /
2 channels used /
2 voies utilisées
T6 ( 85 °C) –40 °C 60 °C 60 °C 60 °C 85 °C 55 °C 85 °C –40 °C –40 °C –40 °C - -
T5 (100 °C) –40 °C 75 °C 75 °C 75 °C 100 °C 70 °C 100 °C –40 °C –40 °C –40 °C - -
T4 (135 °C) –40 °C 76 °C 76 °C 76 °C 135 °C 65 °C 135 °C –40 °C –40 °C –40 °C - -
T3 (200 °C) –40 °C 76 °C 76 °C 76 °C 150 °C 63 °C 150 °C –40 °C –40 °C –40 °C - -