XA01554F-A Micropilot FMR67
16 Endress+Hauser
Position 5 (Housing)
Selected option Description
FMR67 B GT18 dual compartment, 316L
C GT20 dual compartment, Alu, coated
Position 7, 8 (Antenna)
Selected option Description
FMR67 GA Drip-off, PTFE DN50
GP PTFE flush mount DN80
Position 9, 10 (Seal)
Selected option Description
FMR67 A3 FKM Viton GLT, -40...80°C/-40...176°F
A5 FKM Viton GLT, -40...150°C/-40...302°F
A6 FKM Viton GLT, -40...200°C/-40...392°F
Position 11-13 (Process Connection)
Selected option Description
FMR67 AxJ Flange (different sizes), 316/316L
CxJ Flange (different sizes), 316L
GGJ Thread ISO228 G1-1/2, 316L
KxJ Flange (different sizes), 316L
RGJ Thread ANSI MNPT1-1/2, 316L
XxA Align. device (different sizes)
XxG Flange (different sizes), PP
XxJ Flange (different sizes), 316L
Position 14 (Air Purge Connection)
Selected option Description
FMR67 A W/o
1 G1/4
2 NPT1/4
Optional specifications
No options specific to hazardous locations are available.
Safety instructions: General
Staff must meet the following conditions for mounting, electrical installation, commissioning and
maintenance of the device:
Be suitably qualified for their role and the tasks they perform
Be trained in explosion protection
Be familiar with national regulations
Install the device according to the manufacturer's instructions and national regulations.
Do not operate the device outside the specified electrical, thermal and mechanical parameters.
Only use the device in media to which the wetted materials have sufficient durability.