Operating menu Tankside Monitor NRF81
132 Endress+Hauser
"Analog IP" submenu
There is a Analog IP submenu for each Analog I/O module of the device. This
submenu refers to terminals 4 to 8 of this module (the analog input). They are
primarily used to connect an RTD. For terminals 1 to 3 (analog input or output) refer
to →  138.
D
E
F
C
B
A
1
1
1
1 3
2
2 4
1
HR
CDI
WP
on
SIM
2
2
3
3
4
4
1 2 3
4 5 6 7 8
POWER
i
1 2 3 4 5 6 7 8
B
B1-3 B4-8
1 2 3 4 5 6 7 8
C
1 2 3 4 5 6 7 8
C1-3 C4-8
A0032465
 44 Terminals for the "Analog IP" submenu ("B4-8" or "C4-8", respectively)
Navigation  Setup → Advanced setup → Input/output → Analog IP
Operating mode
Navigation  Setup → Advanced setup → Input/output → Analog IP → Operating mode
Description Defines the operating mode of the analog input.
Selection Disabled
RTD temperature input
Gauge power supply
Factory setting Disabled
Additional information
Read access Operator
Write access Maintenance
RTD type
Navigation  Setup → Advanced setup → Input/output → Analog IP → RTD type
Prerequisite Operating mode (→  132) = RTD temperature input
Description Defines the type of the connected RTD.