Tankside Monitor NRF81 Operating menu
Endress+Hauser 163
Selection • AIO B1-3
• AIO C1-3
• Custom
Factory setting Custom
Additional information
Read access Maintenance
Write access Maintenance
Assign PV
Navigation Setup → Advanced setup → Communication → HART output → Configuration
→ Assign PV
Prerequisite PV source (→ 162) = Custom
Description Assigns a tank variable to the primary HART variable (PV).
Selection • None
• Tank level
• Tank ullage
• Measured level
• Distance
• Displacer position
• Water level
• Upper interface level
• Lower interface level
• Bottom level
• Tank reference height
• Liquid temperature
• Vapor temperature
• Air temperature
• Observed density value
• Average profile density
*
• Upper density
• Middle density
• Lower density
• P1 (bottom)
• P2 (middle)
• P3 (top)
• GP 1 value
• GP 2 value
• GP 3 value
• GP 4 value
Factory setting Tank level
* Visibility depends on order options or device settings