Tankside Monitor NRF81 Operating menu
Endress+Hauser 183
Factory setting Gauge
Additional information
Read access Operator
Write access Maintenance
P2 (middle) source
Navigation  Setup → Advanced setup → Application → Tank configuration → Pressure → P2
(middle) source
Description Defines the source of the middle pressure (P2).
Selection Manual value
HART device 1 ... 15 pressure
AIO B1-3 value
AIO C1-3 value
AIP B4-8 value
AIP C4-8 value
Factory setting Manual value
Additional information
Read access Operator
Write access Maintenance
P2 (middle)
Navigation  Setup → Advanced setup → Application → Tank configuration → Pressure → P2
(middle)
Description Shows the pressure (P2) at the middle transmitter.
Additional information
Read access Operator
Write access -
P2 (middle) manual pressure
Navigation  Setup → Advanced setup → Application → Tank configuration → Pressure → P2
(middle) manual pressure
Prerequisite P2 (middle) source (→  183) = Manual value
Description Defines the manual value of the middle pressure (P2).
User entry –25 to 25 bar