Trouble-shooting Levelflex M FMP40 with PROFIBUS PA
106 Endress + Hauser
9.5 Return
The following procedures must be carried out before a transmitter is sent to Endress+Hauser e.g.
for repair or calibration:
Remove all residue which may be present. Pay special attention to the gasket grooves and crevices
where fluid may be present. This is especially important if the fluid is dangerous to health, e.g.
corrosive, poisonous, carcinogenic, radioactive, etc.
Always enclose a duly completed "Declaration of contamination" form (a copy of the “Declaration
of contamination” is included at the end of this operating manual). Only then can Endress
+Hauser transport, examine and repair a returned device.
Enclose special handling instructions if necessary, for example a safety data sheet as per EN 91/
155/EEC.
Additionally specify:
An exact description of the application
The chemical and physical characteristics of the product
A short description of the error that occurred (specify error code if possible)
If necessary, give the error code
9.6 Disposal
In case of disposal please seperate the different components according to their material consistence.
9.7 Software history
9.8 Contact addresses of Endress+Hauser
Contact addresses can be found on our homepage: www.endress.com/worldwide. If you have any
questions, please do not hesitate to contact your Endress+Hauser representative.
Software version / Date Software changed Documentation changes
V 01.02.00 / 04.2002 Original software.
Operated via:
ToF Tool
Commuwin II (as of Version2.05.03)
HART-Communicator DXR375 with Rev. 1, DD 1.
V 01.02.02 / 08.2003 Function group: envelope curve display
Katakana (japanese)
current turn down (HART only)
the customer tank map can be edited
Operated via:
ToF Tool
Commuwin II (as of Version 2.08-1 Update C)
HART-Communicator DXR375 withRev. 1, DD 1.
V 01.02.04 / 07.2004 "mapping" function improved Specification of the measuring accuracy at the end of probe
V 01.02.06 / 01.2005 Function "echo lost" improved
V 01.04.00 / 03.2006 Function "detection window" Description of Instrument Functions
Operating menu extended see Cap. 11.1