Mounting Levelflex M FMP40 with PROFIBUS PA
16 Endress + Hauser
Levelflex M FMP40 - process connection, probe type
Housing dimensions → ä 15
L00-FMP4xxxx-06-00-00-en-007
Fig. 2: Dimensions Levelflex M FMP40
88
88
400
123
2765
80
270...310
Ø 76
Ø 76
SW 50
SW 60
109
109
Ø 60
3 x Ø 8
Ø 67,8
150
20
25
27
20
15
25
100
Ø 76
Ø 81
Threaded connection
G ¾ (¾ BSP)
or ¾ NPT
Threaded connection
G 1 ½ (1 ½BSP)
or 1 ½ NPT
Flange DN 40…200
or equivalent
reference point of
measurement
Variant “2”:
Separator
64.5
rope:
Ø 4 mm/
or
0.16”
Ø 6 mm/0.24”
or
Ø 8 mm/0.32”, coated PA
rope probe rod probe coax probe
Ø 6/0.24” (on ¾” thread)
Ø 16/0.63” (on 1½” thread
or flange)
Ø 21,3/0.84” (on ¾” thread)
Ø 42,4/1.67” (on 1½” thread
or flange)
Ø 22/0.87” (on 4 mm/ rope)0.16”
Ø 30/1.18” (on 6 mm/0.24” rope)
internal thread:
M14 on 4 mm/0.16” rope
M20 on 6 mm/0.24” rope
probe length LN
Probe rods in Alloy C22
consist of 1 piece
(can not be dismantled)
F12 / T12 / F23 housing
M5x0.8
M10x1.0
M10x1.0
4 x Ø 8.5
Ø 60.3
Ø 21.3
98.1
Type of Probe
(see feature 80 in “Ordering structure
”)
Variant “3”:
remote electronic
Variant “4”:
remote electronic
with angled adaptor