Levelflex M FMP40 with PROFIBUS PA Commissioning
Endress + Hauser 75
Display (008)
The distance measured from the reference point to the product surface and the meas. value
calculated with the aid of the empty alignment are displayed again. Check whether the values
correspond to the actual meas. value or the actual distance. The following cases can occur:
Distance correct – meas. value correct -> basic setup completed
Distance incorrect – meas. value incorrect -> a further interference echo mapping must be
carried out "check distance" (051).
Distance correct – meas. value incorrect -> check "empty calibr" (005)
!
Note!
After the basic setup, an evaluation of the measurement with the aid of the envelope curve
("envelope curve" (0E) function group) is recommended ( ä 85).
ENDRESS + HAUSER
E
+
After 3 s, the following message appears
ENDRESS + HAUSER