Proline Promag 300 XA01514D
Endress+Hauser 13
With thermal insulation according to Endress+Hauser specifications
For information on the thermal insulation of the device, see the
"Thermal insulation" section of the "Technical Information"
document
NOTICE
The following applies for devices with order code for "Housing",
Option B "Stainless, hygienic":
Thermal insulation is not allowed.
Promag P high-temperature version
DN Liner T
a
[°C]
T
m
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
15 to 600 PTFE 50 90 130 130 130 130
55 130 130 130 130
25 to 200 PFA 45 95 130 170 170 170
50 90 130 160 160 160