XA01514D Proline Promag 300
12 Endress+Hauser
Medium temperature
Minimum medium temperature:
T
m
= –40 to 0 °C depending on the selected device version (see
nameplate!)
Maximum medium temperature:
T
m
for T6…T1 depending on the maximum ambient temperature T
a
Compact version
Without thermal insulation
Promag H
DN Liner T
a
[°C]
T
m
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
2…150 PFA 50 – 95
1)
130 150 150 150
55 – 80
1)
130 150 150 150
1) The maximum admissible ambient temperature changes for devices with order code for "Housing", Option B
"Stainless, hygienic" in connection with temperature class T5: T
a
= T
a
- 3 K
Promag P
DN Liner T
a
[°C]
T
m
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
15…600 PTFE 50 – 90 130 130 130 130
55 – – 130 130 130 130
25…200 PFA 40 – – – 150 150 150
45 – 95 130 130 130 130
50 – 90 130 130 130 130
Promag P high-temperature version
DN Liner T
a
[°C]
T
m
[°C]
T6
[85 °C]
T5
[100 °C]
T4
[135 °C]
T3
[200 °C]
T2
[300 °C]
T1
[450 °C]
15…600 PTFE 50 – 90 130 130 130 130
55 – – 130 130 130 130
25…200 PFA 45 – 95 130 180 180 180
50 – 90 130 160 160 160