XA01514D Proline Promag 300
16 Endress+Hauser
EtherNet/IP
Supply voltage Input/output 1 Input/output 2 Input/output 3
1 (+) 2 (–) EtherNet/IP
(RJ45 plug)
24 (+) 25 (–) 22 (+) 23 (–)
Device-specific terminal assignment:
adhesive label in terminal cover.
Remote display and operating module DKX001
1
3
81
Vcc
82
Gnd
83
A
84
B
81
Vcc
82
Gnd
83
A
84
B
2
4
5
A0027518
1 Remote display and operating module DKX001
2 Protective earth (PE)
3 Connecting cable
4 Measuring device
5 Protective earth (PE)
Safety-related values
Order code for
"Output; input 1"
Output type Safety-related values
"Output; input 1"
26 (+) 27 (–)
Option BA Current output
4 to 20 mA HART
U
N
= 30 V
DC
U
M
= 250 V
AC
Option GA PROFIBUS PA U
N
= 30 V
DC
U
M
= 250 V
AC
Option MA Modbus RS485 U
N
= 30 V
DC
U
M
= 250 V
AC
Option SA FOUNDATION
Fieldbus
U
N
= 30 V
DC
U
M
= 250 V
AC

Other manuals for Endress+Hauser Proline Promag 300