Proline Promag 300 XA01514D
Endress+Hauser 17
Order code for
"Output; input 1"
Output type Safety-related values
"Output; input 1"
26 (+) 27 (–)
Option NA EtherNet/IP U
N
= 30 V
DC
U
M
= 250 V
AC
Option RA PROFINET U
N
= 30 V
DC
U
M
= 250 V
AC
Order code for
"Output; input 2";
"Output; input 3"
Output type Safety-related values
Output; input 2 Output; input 3
24 (+) 25 (–) 22 (+) 23 (–)
Option B Current output
4 to 20 mA
U
N
= 30 V
DC
U
M
= 250 V
AC
Option D User configurable
input/output
U
N
= 30 V
DC
U
M
= 250 V
AC
Option E Pulse/frequency/
switch output
U
N
= 30 V
DC
U
M
= 250 V
AC
Option F Double pulse output U
N
= 30 V
DC
U
M
= 250 V
AC
Option H Relay output U
N
= 30 V
DC
I
N
=100 mA
DC
/500 mA
AC
U
M
= 250 V
AC
Option I Current input
4 to 20 mA
U
N
= 30 V
DC
U
M
= 250 V
AC
Option J Status input U
N
= 30 V
DC
U
M
= 250 V
AC