XA01514D Proline Promag 300
18 Endress+Hauser
Intrinsically safe values
Order code for
"Output; input 1"
Output type Intrinsically safe values
"Output; input 1"
26 (+) 27 (–)
Option HA PROFIBUS PA Ex i Ex ic
U
i
= 32 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Option TA FOUNDATION
Fieldbus Ex i
Ex ic
U
i
= 32 V
l
i
= 570 mA
P
i
= 8.5 W
L
i
= 10 µH
C
i
= 5 nF
Order code for
"Output; input 2";
"Output; input 3"
Output type Intrinsically safe values
Output; input 2 Output; input 3
24 (+) 25 (–) 22 (+) 23 (–)
Option C Current output
4 to 20 mA Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Option G Pulse/frequency/
switch output Ex i
U
i
= 30 V
l
i
= 100 mA
P
i
= 1.25 W
L
i
= 0
C
i
= 0
Remote display DKX001
Basic specification, position 1,
2
Approval
Terminal assignment Basic specification, position 8
Display; Operation
Option O
Option BS 81, 82, 83, 84
U
n
= 3.3 V
I
n
= 150 mA