Proline Promag L 400 Mounting
Endress+Hauser 23
Reassembling the transmitter housing
!
WARNING
Excessive tightening torque applied to the fixing screws!
Damage to the transmitter.
When reassembling, tighten the fixing screws as per the tightening torque:
Step
(see graphics)
Fixing screw Tightening torques for housing made of:
Aluminum Plastic
1 Housing cover 2.5 Nm (1.8 lbf ft) 1 Nm (0.7 lbf ft)
5 Smart sensor electronics module 0.6 Nm (0.4 lbf ft)
7 Main electronics module 1.5 Nm (1.1 lbf ft)
10 Transmitter housing 5.5 Nm (4.1 lbf ft)
NOTICE
Plug of the smart sensor electronics module connected incorrectly!
No measuring signal is output.
Plug in the plug of the smart sensor electronics module as per the coding.
Reverse the procedure to reassemble the measuring device.
6.2.6 Turning the display module
TX 20
4 x
1.
2.
PUSH TO
REMOVE
PUSH TO
REMOVE
3.
4.
A0021617