Ordering information
NOTE: Endress+Hauser reserves the right to change or modify product, specifications, and ordering informa-
tion at any time without notice. Please consult Endress+Hauser or your local representative for the most recent
information.
The Endress +Hauser service organization can provide detailed ordering information and information on the
order codes on request.
To ensure each meter is programmed to individual requirements, the following information is essential:
Gas type if not air (composition if more than one gas in % volume)
•Gas pressure
Gas temperature
Line size - internal diameter in metric or US units
20 mA range required
Flow engineering units (kg/h, lb/h etc.)
T-masss 65F -
010 020 030 040 050 060 070 080 090 100 110 120
Nominal diameter
15 1/2” (DN15)
25 1” (DN25)
40 1-1/2” (DN40)
50 2” (DN 50)
80 3” (DN80)
1H 4” (DN100)
010 Tube material / sensor material
A 316L SS / 316L SS
B 316L SS / Alloy C22
020 Process connection
K ANSI Class 150 flange, RF, Sch. 40
L ANSI Class 150 flange, RF, Sch. 80
M ANSI Class 300 flange, RF, Sch. 40
N ANSI Class 300 flange, RF, Sch. 80
030 Seal
2 Viton, -4 to +212°F (-20 to +100°C)
3 Kalrez, -4 to +212°F (-20 to +100°C)
4 EPDM, -40 to +212°F (-40 to +100°C)
040 Surface finish
A Basic version
B Cleaned/degreased for Oxygen service
050 Calibration
G Factory calibration, w/o flow conditioner delivered
H Factory calibration with flow conditioner
K Factory calibration, traceable; w/o flow conditioner delivered;
ISO/IEC 17025
L Factory calibration, traceable; with flow conditioner delivered;
ISO/IEC 17025
060 Additional test, certificate
1 Without additional test
2 Material certificate (tube + flange + sensor)
3 Pressure test
4 Material certificate (tube + flange + sensor) plus pressure test
5 CRN approval (only for ANSI flanges)
8 CRN approval + material certificate (tube + flange + sensor) plus
pressure test (only for ANSI flanges)
070 Approval
A Non-hazardous
N FM XP Cl. I, Div. 1 / CSA Cl. I, Div. 1, Grps A-D + Zone 1
(not for housing C)
R FM NI CL, I, Div. 2 / CSA Cl. I, Div. 2, Grps A-D + Zone 2
(not for housing G, not for output/input R, S, T, U)
T-masss 65F Flange Version
080 Housing
A Compact aluminum, NEMA 4X
C Wall mount aluminum, NEMA 4X
G Field housing aluminum, NEMA 4X (not for approvals A, R)
1 Compact aluminum, NEMA 4X, -40°F
3 Wall mount aluminum, NEMA 4X, -40°F
7 Filed housing aluminum, NEMA 4X, -40°F
090 Cable entry
B 1/2” NPT
X Not used, sensor only (only for housing A)
100 Display, operation
7 85 to 260 VAC, without display, remote configuration
(not for housing C)
8 20 to 55 VAC / 16 to 62 VDC without display, remote
configuration (not for housing C)
A 85 to 260 VAC, 2-line display plus push buttons
B 20 to 55 VAC / 16 to 62 VDC, 2-line display plus push buttons
X Sensor only
110 Software
B Factory setup; air
C 1 channel; standard gas / mixture
D 2 channel; standard gas / mixture
E 1 channel; special gas / mixture
F 2 channel; special gas / mixture
X Sensor only
120 Output, input
Fixed I/O modules
A 4 to 20 mA HART + frequency
B 4 to 20 mA HART + frequency + two relays
J Profibus-DP
Q MODBUS RS 485
R 4 to 20 mA HART + 0/4 to 20 mA, passive, Ex-i
(not for approval A, R)
S 4 to 20 mA HART active + frequency passive, Ex-i
(not for approval A, R)
T 4 to 20 mA HART + frequency passive, Ex-i (not for approval A, R)
U 4 to 20 mA HART + 0/4 to 20 mA, passive, Ex-i
(not for approval A, R)
Flexible I/O modules
2 4 to 20 mA HART + frequency + relay + 20 mA input
5 4 to 20 mA HART + frequency + 20 mA input + status input
6 4 to 20 mA HART + status input + 20 mA input (1 x out, 1 x in)
8 4 to 20 mA HART + 20 mA input + frequency + status input
X Sensor only