Heating jacket for Promass A, E, H, I, M, S, P Technical data
Endress+Hauser 11
Flow rate
Heat transfer coefficient
DN Flow rate* in heating jacket in [kg/h]
A H, S, P E I M
1400 ––––
2450––––
4500––––
8 1600 400 700 350
15 1560 440 700 350
25 1520 500 650 350
40 1410 610 560 670
50 1200 850 450 1000
80––––1500
* differencial pressure= 1bar
DN Heat transfer coefficient* α in °C/h
A H, S, P E I M
1150––––
2120––––
480––––
8 210 250 65 220
15 205 235 65 220
25 200 220 60 200
40 180 180 50 165
50 160 100 40 110
80––––25
* uninsulated