Technical data Heating jacket for Promass A, E, H, I, M, S, P
12 Endress+Hauser
4.1.6 Mechanical construction
Design, dimensions → Page 13 ff.
Weight → Page 13 ff.
Materials Heating jackets: 1.4571 / 316 Ti
Material load diagrams Heating jackets
Materials: 1.4571 / 316 Ti
"
Caution!
The following material load diagrams (reference curves) are referring to a temperature range of
–50 to +350 °C (–58 to +662 °F ) But the maximal permissible fluid temperature always depends
on sensor.
A0006939-ae
Fig. 2: Material load through the heating medium (pressure-temperature diagram)
4.1.7 Certificates and approvals
Pressure device approval The devices correspond to article 3 (3) of the EEC guideline 97/23/BG (Pressure Equipment
Directive) and are laid out and manufactured after good engineer practice.
18
19
20
21
22
24
23
25
26
17
[bar]
–50 0 50 100 150 200 250
300 350
[°C]
[psi]
-40
120 200 440 520
[°F]
40 600280 360
280
270
300
290
310
320
330
340
350
260
360
370