Installation RIA14
28 Endress+Hauser
The display can be turned in stages of 90°. First remove the cover clamp (1) and the housing
cover (2). Then remove the display (3) from the electronics unit (4). For configuration purposes,
the ribbon cable between the display and electronics unit has to be plugged in.
Turn the display to the desired position and then attach it to the electronics unit.
3.3.2 Direct wall mounting
Proceed as follows to mount the device directly on the wall:
Drill 2 holes
Attach the device to the wall with 2 screws (5).
3.3.3 Pipe mounting
The mounting bracket is suited for pipes with a diameter between 1.5" - 3.3".
Proceed as follows to mount the device on a pipe:
Attach the mounting bracket to the pipe
The additional mounting plate must be used for pipes with a diameter of 1.5" to 2.2".
Fix the device to the mounting bracket with the two screws supplied. The mounting plate is
not needed for pipes with a diameter of 2.2" - 3.3".
a0011258
Fig. 5: Mounting the field display unit on a pipe with mounting bracket for pipe diameter 1.5-2.2"
Mounting kit, consisting of:
1: Mounting plate
2: Mounting bracket
3: 2 nuts M6