Operating the field display unit RIA14
38 Endress+Hauser
5.4 Configuration via interface & FieldCare Device Setup PC
configuration software
#
Warning!
The device must be configured outside the hazardous area.
"
Caution!
The device can assume undefined states while configuring with FieldCare! This can result in the
undefined switching of outputs and relays.
To configure the device with the FieldCare Device Setup software, connect the device to your
PC. You need a special interface adapter for this purpose - the Commubox FXA291 (see Chapter
’Accessories’).
The 4-pin connector of the interface cable must be plugged into the corresponding socket inside
the device and the USB connector must be plugged into a free USB slot on the PC.
To establish a connection with the device, please follow the FieldCare Operating Instructions.
To then configure the device itself, follow these Operating Instructions for the device. The entire
Setup menu, i.e. all the parameters listed in these Operating Instructions, can also be found in
the FieldCare Device Setup.
Operating
parameters
PARAM
User code
CODE
Program name
PNAME
Firmware version
FWVER
0000 to 9999 0000
NAMUR
NAMUR
NAMUR 3.6*
N_360
NAMUR 3.80*
N_380
Default
Edit
dEF
Edit
0 to NAMUR
20.5
3.60 NAMUR 3.6 to
NAMUR 20.5
3.80
NAMUR 20.5*
N2050
NAMUR 21.0*
N2100
Test
TEST
NAMUR 3.80
to NAMUR
21.0
20.50 NAMUR 20.5
to 25 mA
21.00 off
Open Collect.
Display
OFF
OUT
DISP
Service
SERV
Service code
SCODE
Parameter reset***
PRSET
- - - - Yes
No
Yes
No
Menu Operating function Operating function Operating function
Parameter Default /
Choice
Parameter Default /
Choice
Parameter Default /
Choice
*) only if “Edit” has been selected for NAMUR
**) only if “TEXT” has been selected for DIMENSION
***) only available for service personnel