M215 Installation and Operation
2013 Enphase Energy Inc. 141-00012 Rev 05
Enphase M215 Microinverter Parameters
Features and Specifications
Pairs with most 60-cell PV modules
Dimensions not including mounting bracket (approximate)
17.3 cm x 16.4 cm x 2.5 cm (6.8” x 6.45” x 1.0”)
Enclosure environmental rating
Torque specifications for fasteners
(Do not over torque.)
6 mm (1/4”) mounting hardware: 5 N m (45 to
50 in-lbs) minimum
8 mm (5/16”) mounting hardware: 9 N m (80
to 85 in-lbs) minimum
Torque specification for 10/32 ground cleat
(Do not over torque.)
2 N m (20 to 25 in-lbs) minimum
Natural convection: no fans
http://enphase.com/warranty
UL1741, IEEE1547, FCC Part 15 Class B
CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01
The DC connector has been evaluated and
approved for use as the load-break disconnect
required by the NEC.
The AC connector has been evaluated and
approved for use as the load-break disconnect
required by the NEC.
Engage Cable Specifications
System temperature range (ambient)
-40C to +65C (-40F to 149F)
Conductor insulator rating
Environmental protection rating
UL1741; CAN/CSA C22.2 Nos. 0, 21, 42, 65, 153,
182.1, 182.2, and 182.3; IEC 60529 IP67
Drop connector dimensions
11.8 cm x 6.0 cm x 3.2 cm
(4.64” x 2.36” x 1.25”)
Terminator cap dimensions
3.6 cm diameter x 5.1 cm tall (1.4” x 2”)