Epever DR3210N-DDS - PV Array Configuration; PV Array Module Configuration Guidelines

Epever DR3210N-DDS
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
DR1106/2106/3106/1206/2206/3206N-DDB/DDS:
System
voltage
36cell
Voc<23V
48cell
Voc<31V
54cell
Voc<34V
60cell
Voc<38V
Max.
Best
Max.
Best
Max.
Best
Max.
Best
12V
2
2
1
1
1
1
1
1
24V
2
2
-
-
-
-
-
-
System
voltage
72cell Voc<46V
96cell Voc<62V
Thin-Film
module
Voc>80V
Max.
Best
Max.
Best
12V
1
1
-
-
-
24V
1
1
-
-
-
NOTE: The above parameter values are calculated under standard test conditions
(STC(Standard Test Condition): Irradiance 1000W/m
2
, Module Temperature 25℃, Air
Mass 1.5.)
DR2210/3210N-DDB/DDS:
System
voltage
36cell
Voc<23V
48cell
Voc<31V
54cell
Voc<34V
60cell
Voc<38V
Max.
Best
Max.
Best
Max.
Best
Max.
Best
12V
4
2
2
1
2
1
2
1
24V
4
3
2
2
2
2
2
2
System
voltage
72cell Voc<46V
96cell Voc<62V
Thin-Film
module
Voc>80V
Max.
Best
Max.
Best
12V
2
1
1
1
1
24V
2
1
1
1
1
NOTE: The above parameter values are calculated under standard test conditions
(STC(Standard Test Condition): Irradiance 1000W/m
2
, Module Temperature 25℃, Air
Mass 1.5.)
2.3 Wire Size
The wiring and installation methods must conform to national and local electrical code
requirements.