27
4 Others
4.1 Protections
PV Over
Current/Power
When the charging current or power of the PV array exceeds
the controller's rated current or power, it will change at the
rated current or power.
PV Short Circuit
When not in the PV charging state, the controller will not be
damaged in case of a short-circuiting in the PV array.
PV Reverse Polarity
When the polarity of the PV array is reversed, the controller
may not be damaged and can continue to operate normally
after the polarity is corrected.
NOTE: If the PV array is reversed and the actual power is
1.5 times the rated controller's power, the controller will
be damaged.
Night Reverse
Charging
Prevent the battery from discharging to the PV module at
night.
BATT1 and BATT2
Reverse Polarity
When the polarity of the battery is reversed, the controller
may not be damaged and resume normal operation after the
mis-wiring is corrected.
NOTE: Limited to the lithium battery's characteristic,
when the PV connection is correct, either the BATT1 or
BATT2 battery connection reversed, the controller will
be damaged.
BATT1 Over
Voltage
When the battery voltage reaches the over voltage
disconnect voltage, it will automatically stop battery charging
to prevent battery damage caused by over-charging.
BATT1 Over
Discharge
When the battery voltage reaches the low voltage
disconnect voltage, it will automatically stop battery
discharging to prevent battery damage caused by
over-discharging. (Any controller connected to the loads will
be disconnected. Loads directly connected to the battery will
not be affected and may continue to discharge the battery.)
BATT1 Overheating
The controller can detect the battery temperature through an
external temperature sensor. The controller stops working
when its temperature exceeds 65 °C and restarts to work