40
RFRPD Room Thermostat CP4D
This function allows the user to activate or deactivate frost protection.
Frost protection can be set from 5…15°C.
When frost protection is activated, the thermostat will switch on the boiler
when the temperature drops below the setpoint.
Frost protection is only active in OFF mode and Holiday mode.
Press and hold
PROG
and for 5 seconds.
‘P01’ will appear on the screen.
Rotate
clockwise until ‘P05 & Fr’ appears on the screen.
Press
to select. ‘ON’ will ash on the screen.
You now have two choices:
1. Press
to conrm frost protection,
Rotate
to select the frost protection temperature between 5…15°C.
Press
to conrm and you will return to the menu.
2. Rotate
anticlockwise to turn the frost protection OFF.
Press
to conrm and you will return to the menu.
Press
AUTO
to return to the home screen.
P0 5 Frost Protection
5˚C