3.2.3.5 Power Supply Unit (PWB-E) Removal
1. Remove the upper unit. (Refer to Section 3.2.3.3.)
2. Remove 6 screws (#4:2, #7:2), and remove the PWB-E cover.
3. Disconnect connector CN207 from the C169 MAIN-B Board.
4. Remove 4 screws (#4) and 2 screws (#6), and remove the PWB-E.
Figure 3-13. Remove the PWB-E Cover
Figure 3-14. Removing the PWB-E