EPSON Stylus Photo R200/R210 Revision A
DISASSEMBLY AND ASSEMBLY Disassembly 51
2.3.11 Carriage Unit removal
o External View
Figure 2-22. "Carriage Unit" removal (1)
o Parts/Units which should be removed before removing "Carriage Unit"
Paper Support Assy./Housing (left/right)/Housing (frame)/APG Unit/Print Head
o Disassembly Procedure
1. Remove the screw (x7) for securing "Guide Plate, CR".
2. Remove "Fixed Spring, CR Shaft, Left" by releasing it from the hook of
"Frame, Main".
3. Release the ribs (x2) for securing "Guide Plate, CR", and remove "Guide
Plate, CR" while stepping aside the hook which has secured "Fixed Spring,
CR Shaft, Left".
4. Remove the right side of "CR Scale" from "Holder, Scale Right".
5. Pull out "CR Scale" from the back of "Carriage Unit" to the left. Then, release
"CR Scale" from one of two hooks of "Holder, Scale, Left" first, and next
release "Extension Spring, 3.289" from the other hook.
6. Remove "Extension Spring, 3.289" from "CR Scale".
7. Loosen the tension of "Timing Belt" by pushing "Pulley, Driven" to the right.
Then, remove "Timing Belt" from the pinion gear of "CR Motor" first, and
then from "Pulley, Driven".
Cover, Guide Plate, CR
Hooks
Dowel
Carriage Unit
Fixed
Spring, CR
Shaft, Left
Hook
2
3
6
Rib
1
4
5
Rib
Extension Spring, 3.289
Holder, Scale Left
Hook
Hook
Pulley, Driven
Holder, Scale Right
Hook
CR Scale
Timing Belt
Pinion Gear
C.B.S 3x6 (7-9kgf•cm)
Guide Plate, CR