Stylus Pro 4000 Field Repair Guide 4/28/05
  Printer Component, Software Item, LCD Display, Printer Button  Page 8.
Elec.: Record: Maintenance: (Usage Counters for the following devices) WasteInk, Wiper, Rubbing, 
Lever, Cover, Ink Lever, Cr Motor, PF Motor, PrintNumber, Cleaning, Fire A, Fire B, Fire C, Fire 
D, Fire E, Fire F, Fire G, Fire H, Cut, Cute Sole, LockSolen
Record: Error: Error (0 - 6) (Displays the last 7 errors)
D/A Revision: Measure Va: (nn.nnn)v (?)
CSIC: Slot (1 - 8), Maintenance Tank (?)
Actuator: Cutter: [Enter], Start (Tests the cutter assembly)
Actuator2: Cutter Sol, Pump Motor (Tests the following devices)
Adjustment: 
Cut Adj.: Pressure: *73% (Adjusts voltage used for the cutter solenoid)
PG ADJ: [Enter], Start: PG Offset *(nn) (Used for adjusting the platen gap)
Rear AD: [Enter], Start: Exc.: RearAD: (nnn nnn nnn) (For adjusting the rear paper sensor)
Edge Sns Lvl: [Enter], Start: (For adjusting the sensitivity of the edge sensor)
Check Nozzle: [Enter] Print: (Service level nozzle check)
Check Skew: Check Skew: (n.n)mm (Default 1.0) (Used for setting the amount of allowable skew)
Clean Head: (Used for draining the ink system)
Counter Clear: Reset Counter? (Resets all counters, DO NOT USE)
Ink Drain: (Used for draining the ink system)
Cleaning: 
Std. KK0 (Weakest cleaning cycle (uses less ink))
Std. KK1 (Medium strength cleaning cycle)
Std. KK2 (Strongest cleaning cycle)
Init. Fill (Forces a initial fill (prime))
Print: 
Check Ptn.: [Enter] Print (Prints all alignment patterns)
Adj. Variable: [Enter] Print (Prints the numeric adjustment variables currently set)
Parameter: 
Initialize: 
All: Initialize OK? (Resets all of the following counters at once)