Stylus Pro 4000 Field Repair Guide 4/28/05
Pump and Cap Installation Printer Component, Software Item, LCD Display, Printer Button Page 88.
3. Insert the Cap Assembly part of the way, through the back of the Printer.
4. Install the 4 Screws securing the Cap and Pump Assembly. Ensure that the Assembly is
correctly seated to avoid carriage errors.
Slide the Cap and Pump
Assembly, part of the way in
Feed the Tubes into the receptacle
Assist the Tubes fully into the receptacle,
while sliding in the Assembly.
If the Ink Tubes
are not fully
inserted, the
Ink may bubble
back through
the cap.
2 Screws
2 Screws
Ensure that the Flushing
Box Screw Hole is correctly
aligned before tightening the
Assembly screws.